Chicago Repair and Replacement Parts Network   >   By Location   >   Addison   >   Fans and Blower   >   Radiation geiger detector dosimeter radex 1706 english

Radiation geiger detector dosimeter radex 1706 english


Radiation geiger detector dosimeter radex 1706 english
Detector Radiation / Monitor / GEIGER COUNTER RADEX RD1706 / RD 1706
Photobucket We d like to call your attention new elaboration RADEX RD1706 in the family of RADEX radiation monitors. The device can be used not only by the population in day-to-day life but by the personnel operating with ionizing radiation sources as well.
Photobucket The time from the moment of release of the radiation monitor RADEX RD1503 has demonstrate that some consumers wish to have the indicator of radio-activity with a reduced time of observation, expanded range of indications, better precision of indications and ability to register x-ray radiation. All these requests are summarize and implemented in RADEX RD1706 model. This device has retained BACKGROUND mode used in RD1503 + which is very convenient for performing inspections inside buildings and purchasing building materials; vibra signal having a good account is also retained as the additional feature of the alarm system.
Photobucket There are two SBM20-1 type Gejgera Muller counters of hard beta and gamma radiations in RADEX RD1706, which technical characteristics can be observed here. It allows to reduce the time of observation from 40 till 26 seconds and to improve precision of indications. The range of indications is essentially expanded (100 times in comparison with RADEX RD1503); RD1706 can register the value of a doze rate till 999,0 Sv/h, thus time of observation smoothly reduced from 26 to 1 second what is necessary for the stuff operating with ionizing radiation sources.
Photobucket Everything that has been approved by users is retained in RADEX RD1706, i.e. the usual frame with a large LCD, three buttons and individual settings like various threshold signal actuation, indications on battery charge, display backlighting.
Improvements of RADEX RD1706 comparing to the basic model RADEX RD1503
Photobucket ability to register gamma, beta and x-ray radiation;
Photobucket expanded range of indications (up to 999,0 Sv/h);
Photobucket time of observation is reduced from 1 to 26 sec.;
Photobucket time of observation gradually reduces from 26 to 1 sec. when the value of a dose rate is higher than 3,5 Sv/h;
Photobucket improved precision of indications;
Photobucket the ability to set threshold level indications up to 99,0 Sv/h (100 times in comparison with RADEX RD1503);
Photobucket BACKGROUND mode for performing inspections inside premises using algorithm similar to methodical instructions MU 2.6.1.715-98 Conducting a radiationally-hygienic inspection of inhabited and public buildings;
Photobucket displaying the value of a background dose rate;
Photobucket displaying the difference in indications between the average dose rate and a background dose rate;
Photobucket value of a background dose rate is saved after turning off the device;
Photobucket displaying an average dose rate exceeding over a background dose rate;
Photobucket vibra-call signal as the additional alarming function;
Photobucket possibility to regulate a vibra signal (turning on/off);
Photobucket RADEX RD1706 evaluates the ambient equivalent of dose rate H*(10) of gamma radiation with taking into account gamma radiation and the pollution of objects by sources of beta particles.
Photobucket The device can be used by the population in day-to-day life (foodstuff, building materials, soil etc.) and by the personnel operating with ionizing radiation sources.
Photobucket RADEX RD1706 evaluates the value of beta and gamma radiation by the means of two SBM20-1 type Gejgera Muller counters and displays the indications in Sv/h on LCD. The time of observation a dose rate and varies from 40 to 26 seconds.
Photobucket Registration of every particle is accompanied with a sound signal what makes it easer to search for the source of radiation.
Photobucket The device possesses BACKGROUND mode which gives not just one but two indications. One stands for exceeding of a dose rate over a background dose rate, the second stands for a background dose rate. This mode is convenient for examining inside buildings, when it is necessary to know how indications indoors differ from the ones outdoors.
Photobucket The device possesses next features:
Photobucket specification of indications in proportion of increase of monitoring time,
Photobucket turning on/off display backlight,
Photobucket turning on/off audio and vibra signals.
Photobucket MENU is written in ENGLISH.
Range of ambient equivalent of dose rate indications H*(10)
Range of registered gamma radiation energy
Range of registered X-ray radiation energy
Range of registered beta radiation energy
Reproducibility of indications (at confidential probability 0.95) where P is a doze rate in Sv/h
Time of continuous work of the device, not less than
Overall dimensions height x breadth x depth not more than
Weight (without power elements) not more than
1. Period of observation shortens with the increase of a dose rate more than 3,0 Sv/h.
2. The increase in the number of performed cycles improves the reliability of indications.
1. On the basis of manufactures settings, background dose rate not higher than 0,3 Sv/h and two batteries with a capacity of 1350 mAh.
2. The device can operate with one power element AAA type (but the time of continuous operating reduces).
* Device RADEX RD1706 (menu is written in ENGLISH),
* 2 power elements, size AAA ,
Photobucket Any unauthorized, improperly packaged, or non-insured returns will be returned to sender.
(Radiation geiger detector dosimeter radex 1706 english was posted and is owned by: Tommy Heath)
Contact: t.heath@chicagopartsnetwork.com (Tommy Heath) (actual email hidden)
Contact t.heath@chicagopartsnetwork.com (Tommy Heath) for more information.

Flag any violation to moderators committee

Your flagging message:




Radiation geiger detector dosimeter radex 1706 english