BANNER ENGINEERING CORPORATION
Features floating blanking (one- or two-beam), which is easily configured inside the control module
Selectable auto power-up mode for applications where a key reset is difficult to perform
Gray polycarbonate housing designed to bolt directly to enclosure backplate or mount onto standard 35 mm DIN rail
Two-digit display provides diagnostic information and indicates number of channels blocked
Includes input for Emergency Stop function
Choose models with either trip or latching outputs
Select models with either two or four FSD output contacts
Removable plug-in wiring blocks
MICRO-SCREEN DIN Module Controllers Specifications
Per requirements IEC 61496-1 (Type 4)
Size: Material: gray polycarbonate, clear polycarbonate cover. Rating: NEMA 1, (IP 20)
2 amp, 250 V (3 AG or 5 x 20 mm slow blow)
24V dc 15%, 10% maximum ripple, 1.5 amps max.
Status Indicators (on control box and receiver)
Red = BLOCKED Flashing red = LOCKOUT
= CLEAR Flashing green = BLANKING ON
= RESET Double-flashing yellow = Waiting for Power-up Key Reset
= ALIGNMENT. Flash rate increases with the number of sensing beams
made , solid yellow when aligned and defined area is clear.
Two-digit numeric display indicates cause of lockout condition and total number of beams blocked
Keyed Reset of system lockout conditions
Floating Blanking selection switches and Fixed Blanking programming switches
Emergency Stop actuator must offer two normally closed contacts and be capable of switching 50 mA
@ 30V dc. Total resistance limit of 30
. Functional stop category 0 per NFPA 79 and EN 418, Safety
Simultaneity requirement < 100 ms
Reed relay; 125V ac or dc max., 500 mA max. (10VA maximum, resistive load)
Output Configuration(FSD1, FSD2, and SSD)
Forced-guided contact relay (resistive load).
FSD1 & 2, SSD = 250V ac max., 4 amp max.
10,000,000 operations (minimum).
100,000 operations (typical @1.0kVA switching power).
Arc suppression is recommended when switching inductive loads. See Warning on page 252.
Note: Controllers with model suffix
2 have two FSD output contacts and those with model suffix 4
have four FSD output contacts.
Temperature: 0 to +50 C (+32 to 122 F)
Light Screen: Less than 38 ms (all lengths)
Use of fixed blanking requires sensors with 16 or more light beams. Up to 12 beams or 30% of the
total number of beams in the array may be blanked, whichever is less. Call factory for applications
assistance if a greater number of blanked beams is required.
(Banner micro-screen din module controller usdint 1L2 was posted and is owned by: Bryan Stewart)
Contact: B_Stewart@chicagopartsnetwork.com (Bryan Stewart) (actual email hidden)
Contact B_Stewart@chicagopartsnetwork.com (Bryan Stewart) for more information.

Flag any violation to moderators committee

Your flagging message:




Banner micro-screen din module controller usdint 1L2