Chicago Repair and Replacement Parts Network   >   By County   >   DuPage County   >   Fans and Blower   >   Edwards active strain gauge package vacuum pressure

Edwards active strain gauge package vacuum pressure


Edwards active strain gauge package vacuum pressure
This is a complete Edwards active strain gauge package, providing gas independent pressure measurement from 2000 mbar to 1 mbar.
The controller and sensor were tested on a clean high vacuum system. As we already had another cable readily available to use, the 3 m cable was left in its sealed plastic bag. During pump-down, indicated pressures correlated sensibly with those from a "known good" convection-enhanced Pirani gauge operated simulataneously on the same system. At high vacuum, the strain gauge was zeroed as described in the manual (was initially within 5 mbar of zero). After venting the system back up to atmospheric pressure, the pressure indicated was 1009 mbar, at which time the Weather Channel was reporting 29.90 inches of mercury, or 1012 mbar. We do not have the equipment to accurately produce positive pressures to test it at 2000 mbar, but the tests just described are sufficient to make us think that this package is functioning correctly.
ADD Active Digital Display - NEW condition:
* Edwards part number D39556000
* 4-digit digital display; bright, easy-to-read LEDs
* can be easily configured to read in either mbar or in torr (currently set to read in mbar)
* chart recorder output: 0-10 VDC, linear
* 90-120 VAC or 185-265 VAC (switchable), 45-70 Hz mains
* brackets and screws (for panel mounting)
* fold-up front feet, mounting screws, and self-adhesive back feet (for free-standing use)
* mating connector for chart recorder output
ASG Active Strain Gauge - NEW condition:
* Edwards part number D35728000
* pressure range: 2000 mbar to 1 mbar
* operating temperature: -20 to 125 C
* ambient humidity 10 to 90% (non-condensing)
* maximum overpressure: 2x full scale with negligible calibration change
* accuracy: +/- 0.2% full scale
* stability: 0.2% full scale
* temperature coefficient: 0.05% full scale per C
* materials exposed to vacuum: 316L stainless steel
* short adapter cable (assembled to the connector for the sensor)
* gauge cable (for completing the run to the display unit) - 3 m in length
If a longer cable is needed, then please ask. For a very modest additional cost, we can include a 25-foot commercial Category 5e patch cable assembly with strain relieved connectors. In our experience, these work just fine with the Edwards active gauges.
(Edwards active strain gauge package vacuum pressure was posted and is owned by: Louisa Velazquez)
Contact: Louisa-Velazquez@chicagopartsnetwork.com (Louisa Velazquez) (actual email hidden)
Contact Louisa-Velazquez@chicagopartsnetwork.com (Louisa Velazquez) for more information.

Flag any violation to moderators committee

Your flagging message:




Edwards active strain gauge package vacuum pressure